Category: Case Reports

Dry Eye and Scleral Lenses

[us_post_title][us_post_date]

By Dr. Elise Kramer, OD, FAAO, FSLS

A 71-year-old man presented to the Miami Contact Lens Institute for a scleral lens refit. He was wearing his scleral lenses but complained of significant lens awareness and foggy, dirty lenses. He reported having worn the lens only four times since they were originally dispensed because of discomfort. A review of his ocular history revealed severe keratoconjunctivitis sicca caused by Sjögren’s syndrome and acquired toxoplasmosis of the left eye. The patient reported that the latter was no longer active but that owing to a recent flare-up, he had retinochoroiditis, leaving him with very poor central vision in that eye. He had no history of glaucoma or trauma and no family history of ocular disease. In addition, he had a history of hypertension, hyperlipidemia, anxiety, depression, and prostate cancer.

He had been taking 20 mg of Plaquenil daily for the last 10 years, prescribed for his Sjögren’s syndrome. For his dry eye symptoms, he was using over-the-counter artificial tear drops, autologous serum eye drops and topical steroids, and had had plugs inserted in all four punctae. Despite these treatments, the patient continued to have severe ocular dryness, for which scleral lenses had been fitted. Visual acuities with his current scleral contact lenses (ScCLs) were 20/60 in the right eye and 20/400 in the left eye. His pupils were equal, round and reactive to direct and consensual illumination, and no afferent pupillary defect was observed in either eye. Confrontational visual fields were full to finger counting in both eyes, and extraocular motility was full in both eyes. The patient had moderate scurf in his eyelashes, which he had been cleaning daily using OcuSoft lid wipes. He had moderate capping of his Meibomian glands, white and quiet conjunctivae, flat irides and clear lenses bilaterally. Slit lamp examination revealed scleral lenses in place in both eyes with sizeable zones of poor wettability, protein and lipid build-up centrally. (Figure 1)

 
[us_image image=”8109″ align=”center”]

Figure 1. Right eye with scleral lens in place showing significant deposits on the temporal and central portion of the lens.

After the lenses were removed, the ocular surface was examined with a slit lamp. The corneas had mild diffuse staining, as did the conjunctivae. The patient had a low tear meniscus in both eyes. He had flat irides and mild nuclear sclerosis in both eyes. No proptosis or lid abnormalities were observed in either eye. After instilling one drop of 0.5% proparacaine hydrochloride ophthalmic solution at 11:00 AM, intraocular pressures were measured by Goldmann applanation tonometry as 13 mm Hg OU. On dilated fundus examination (after instilling one drop of a solution of 1% tropicamide and 2.5% phenylephrine OU), the cup-to-disc ratios were 0.2 OU. The neuroretinal rims were healthy and pink in both eyes. The macula was clear and flat in the right eye, but the left eye had a very large, white/yellow scar extending from the macula to the peripheral vascular arcades. The vitreous was clear in both eyes, with no signs of active inflammation. The retinal vasculature was of normal course and calibre in both eyes, and no breaks were observed in the retinal periphery.

 

[us_image image=”8111″ align=”center”]

Figure 2. Right eye showing new scleral lens with smooth surface free of deposits

Discussion

Nearly five million Americans over the age of 50 suffer from dry eye. Thirty million, in general, have symptoms of dry eye disease but only 16 million are diagnosed, and one million treated.1 In fact, it is the number one reason that patients visit their eye care practitioners.2 There is huge potential to address this highly prevalent condition. Optimal management can be achieved by basing the treatment on the etiology and severity of the dry eye3 but can be very challenging in severe cases.4 Scleral lenses are now well established in treating dry eye disease, especially in refractory cases where traditional treatments have limited efficacy.4 Current literature recommends the use of contact lenses for Grade 3 dry eye,5 i.e., chronic dry eye that affects comfort and vision.3  They should be considered as a management option when conventional treatments are insufficient and after having tried prescription medications and overnight treatments such as ointments or moisture goggles, and before long term use of steroids, amniotic membrane grafts, surgical punctal occlusion or other procedures such as tarsorrhaphy or salivary gland transplantation.3

Not all lenses are appropriate for severe dry eye, however. In fact, some can do more harm than good. Scleral lenses can be beneficial in these cases by promoting patient comfort and visual function.4

These lenses are custom-made for each patient and are fitted in a way to vault the cornea and maintain a constant reservoir of fluid between the lens and cornea to ensure that the cornea remains hydrated. This fluid reservoir acts as a liquid bandage that protects the ocular surface from the environment and from friction caused by blinking the eyelids. It also compensates for surface irregularities, leading to improved vision. Other types of contact lenses may be limited by the compromised state of the ocular surface. Scleral lens designs can overcome these challenges. They work especially well for vision correction because the fluid layer helps smooth out defects caused by dry eyes, providing a more uniform refractive surface.

The material chosen in the case presented was Optimum Extra (Contamac), which is specifically indicated in dry eye syndrome and provides the comfort of a soft lens with higher optical quality.6 Its DK of 100 allows the lenses to be permeable to oxygen. The coating that was added to the lenses (Tangible Hydra-PEG™) is an advanced contact lens coating technology that encapsulates Contamac Optimum’s gas-permeable material in an ultra-thin layer of PEG-based polymer. The result is called Optimum | Tangible Hydra-PEG™. It creates a highly wettable and lubricated surface, with increased surface water retention due to the polyethylene glycol-based polymer’s high water content (90%) and resistance to protein and lipid deposits, which reduces friction between the eyelid and contact lens. It is therefore particularly suited to contact lens wearers who suffer discomfort due to a number of physiological conditions, such as dry eye.6

In summary, by upgrading the material of the patient’s lenses and adding the Tangible Hydra-PEG™ coating, we were able to improve his comfort and increase his wear time. He was able to wear the lenses comfortably for 12-16 hours per day and reported substantial improvement in his dry eye symptoms. With the increasing recent interest of clinicians and manufacturers, scleral lenses have become “mainstream” in contact lens practice. Dry eye diagnosis and management have also had an increasing interest amongst practitioners. Eye care practitioners should continuously update their expertise in the area of scleral lens design, which can be an excellent management strategy for patients with dry eye and many other ocular problems.


1. The epidemiology of dry eye disease: report of the Epidemiology Subcommittee of the International Dry Eye WorkShop (2007). Ocul Surf. 2007 Apr;5(2):93-107.
2. Gayton JL. Etiology, prevalence, and treatment of dry eye disease. Clin Ophthalmol. 2009;3:405-412.
3. DeNaeyer G. Scleral Lenses: An Overlooked Fix for Dry Eye? Review of Cornea and Contact Lenses 2013, April.
4. Bavinger JC, DeLoss K, Mian SI. Scleral lens use in dry eye syndrome. Curr Opin Ophthalmol. 2015 Jul;26(4):319-24.
5. Jones, L. Downie, LE. Korb, D, et al. TFOS DEWS II Management and Therapy Report. The Ocular Surface. 2017 Jul; 15(3):575-628. Doi:10:1016/j.tos.2017.05.006.Epub
6. Contamac, www.contamac.com/product/optimum.

Thank you to Dr. Elise Kramer, O.D. for contributing to Global Insight.

[us_image image=”7938″]

Dr. Elise Kramer OD, FAAO, FSLS
Optometrist and Contact Lens Specialist
Residency Coordinator, Scleral Lens Education Society (SLS)
Former resident at the Miami VAMC and Bascom Palmer Eye Institute 2012-13
University of Montreal School of Optometry graduate ’12

[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin”]

Introducing a new addition to the Optimum family of materials

[us_post_title][us_post_date]

The Optimum range of materials has become established as one of the most popular RGP materials on the market. Recent years have seen remarkable growth in the usage of both ortho-k and scleral lens usage and, in response to this Contamac have developed Optimum Infinite, a hyper-Dk material which cuts like a regular material and wets without the need for plasma or surface coating. The material has a Dk of 180 yet, unlike other high Dk materials, does not flex, making it ideally suitable for both scleral and overnight wear ortho-k use.

It is also useful for high oxygen demand corneae, such as in the case below kindly submitted by Michael Wyss of Eyeness AG, Switzerland.

Patient 

MB Male, aged 64 years

Medical History

Chronic Sarcoidosis and Rheumatoid Arthritis, Glaucoma. RE AMD (no usable vision).

Handling issues because of arthritis – extended wear RGP lens worn LE only.

Spectacles 

BCVA with specs 0.5 LE

Contact Lenses 

BCVA with Cl 1.0 LE (-3.00)

Hypoxia-related problems including corneal edema and endothelial blebs with current lens (Dk 125) reduced comfort and visual acuity.

BCVA with Cl reduced to L 0.2.

Topography 

Optimum Infinite CS - Oculus reading
Left eye topography showing distortion

Contact Lenses

Original L Lens + Fl

Same lens design but in Optimum Infinite

Edema and distortion reduced, visual acuity improved to 1.0, extended wear now resumed up to 1 week.

[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

An Update on Scleral Lenses

[us_post_title][us_post_date]

By Martin Conway

Scleral lens use has been growing steadily over the past decade, driven mainly by the U.S. market where scleral fitting has dominated discussions in clinical publications for the past four years or more. This growth in usage has been matched by the growth in laboratories offering scleral lens designs. Once the province of a few specialist manufacturers, most laboratories now offer a design, either of their own, or licensed from a foreign manufacturer.

I can think of no previous occasion when the profession’s top researchers from all over the globe, but in particular the United States, all shared a specific focus on a single modality. This concentration of minds has resulted in a rapid accumulation of knowledge that has resulted in novel designs that are almost immediately available to the practitioner.

The reason for this meteoric rise in popularity has a lot to do with the fact that the scleral lens offers huge advantages to practitioners, laboratories and, most importantly, to patients. Patients with difficult, irregular corneae or dry eyes can now achieve visual acuities normally only obtained with a corneal GP lens, yet with comfort levels associated with soft lenses or, in some cases, even greater. Laboratories can command higher prices that practitioners can pass on to patients prepared to pay for the life-changing benefits that this modality can offer. All without the fear that the internet is going to undermine their investment.

There are some issues yet to be resolved however, and any practitioner thinking of introducing sclerals to their practice should be aware of them.

Scleral Shape

Our previous knowledge of scleral shape has proven to have been incomplete. Increased research effort, coupled with advances in technology has gone a long way to improving that position.

We now know that the sclera shape is not what we once thought of as a clearly delineated curve, separate from the limbus. OCT imaging shows a contiguous line of tissue with little change of curvature. Little was known of the shape of the sclera beyond the immediate limbal area but recent research using a new wide-field topographer has explained what some of had been beginning to suspect. The traditional spherical shape of conventional sclerals may need to be rethought. This research conducted by members of the Scleral Lens Shape Study Group¹ (SLSSG) used data collected at 14. 15 and 16mm from corneal centre to classify scleral shape into four groups as shown below.

Scleral Surface Patterns Observed in 140 Scleral Lens Patients

Group Pattern Description N%
1 Spherical 8 (5.7%)
2 Toric-Regular 40 (28.6%)
3 Asymmetric High or Low Points 57 (40.7%)
4 Periodicity different from 180º 35 (25%)


It would suggest that a spherical periphery is only really suitable in under 6% of cases and 70%+ of eyes would be better served with a toric periphery, and some might even need a more complex design still. Many practitioners who have been fitting sclerals for some time had come to this conclusion on their own, and labs are reporting usage of toric peripheries in as much as 70% of new fits. This ties neatly into the figures from the research. Many labs are now incorporating this feature as standard in their fitting set lenses.

Fogging

These findings may go some way to explain a phenomenon peculiar to sclerals – “Mid-day Fogging” as it is known has been an annoying feature for some wearers. After a few hours wear the tear film becomes increasingly cloudy until the patient needs to take off the lens, rinse, replace the insertion fluid and reinsert the lens to maintain clear vision. The following images are of a patient I saw recently:

Mr. T. – The tear film at 8 hours wear is clearly “foggy”, resulting in reduced vision.

Horizontal section through edge looks good.

Instilling Fluorescein into the eye without removing the lens soon identifies to source of the problem.

Fig 1 Fig 2 Fig 3


Within seconds of instilling Fluorescein, the dye encroaches under the lens at 5 and 11 o’clock ( Figs 1 and 2). Within minutes the two plumes of dye have merged in Fig 3. A scleral lens should be a sealed system. Once initial settling has occurred, it should be impossible for contaminants to enter the post-lens tear reservoir. In this case, although the lens was fitting well along the 180 meridian, it was rocking under the influence of the blink to pump lipids under the lens and form the suspension seen in the OCT image above. In extreme cases, edge standoff can result in conjunctival prolapse, where a conjunctival flap is sucked up under the lens by the suction caused by the lens rocking. In more subtle cases, the incomplete seal is barely noticeable through the slit lamp, but is sufficient to allow lipids to enter under the lens and cause fogging.

Refitting the lens with a toric periphery and reducing the central clearance by 100 microns solved the problem.

OCT Imaging

Traditionally, scleral lenses are fitted using fluorescein and observing the thickness of the tear layer through a narrow slit lamp beam at 45° to the eyepiece. The vault is assessed by comparing the thickness of the film to the known thickness of the trial lens. This method is subject to error however, and the greater availability of OCT imaging in practice now permits a much more accurate measurement of clearances and permits

OCT permits accurate measurements

As with most other lens types the secret of a comfortable lens lies in the design and the alignment of the edge. The OCT permits the practitioner to view the edge profile in detail. Not all lenses are the same!

Poor edge shape

Nicely rounded edge spreads weight over larger surface area resulting in increased comfort


Dk and Scleral Lenses

Whilst there is little doubt that scleral lenses are here to stay, we should still be mindful of the fact that today’s lenses are made from traditional GP materials that were designed for use in corneal lenses that are half the thickness of a scleral. This, combined with the fact that the tear layer has a Dk of around 80 means that we are significantly reducing the amount of oxygen passing through the lens/tear combination when compared to a corneal lens. On top of this, the scleral lens does not benefit from the tear pump action to replenish the tear reservoir – it is effectively a sealed system.

Most of the work done on this subject is based upon mathematical modelling and suggestions of minima for Dk and lens clearances are all therefore theoretical. Clinical observations are suggesting that other mechanisms may be at work that are supplementing the oxygen supply beyond the mathematical model’s restrictions.

This may have something to do with the fact that the mathematical model treats the tear layer as another lens, where in fact it is a fluid. Mixing of the tear lens layer occurs during the blink as we have seen with the fluorescein images above, and this may well assist the passage of dissolved oxygen through that layer and boost the eventual amount of oxygen reaching the cornea.

Conclusion

Sclerals are exciting interest around the world and are offering solutions for many patients, some of whom have struggled for years. There are still some unanswered questions however, and that is part of what makes this modality so intriguing. There is no doubt that we will learn more as we progress. The use of new instrumentation will make fitting more precise, and designs will improve to eliminate fogging and other issues. In the meantime many patients are now reaping the benefit of the recent whirlwind development of this exciting market development.

Thank you to Tom Arnold OD, FSLS, Owner & Optometrist, Today’s Vision Sugar Land, P.A for contributing the feature imagery to this article. 


1. DeNaeyer G, Sanders D, van der Worp E, Jedlicka J, Michaud L, Morrison S. Qualitative Assessment of Scleral Shape Patterns Using a New Wide Field Ocular Surface Elevation Topographer. JCLRS [Internet]. 16Nov.2017 [cited 30May2018];1(1):12-. Available from: http://www.jclrs.org/index.php/JCLRS/article/view/11
[us_separator size=”small” show_line=”1″]
[us_image image=”10392″ has_ratio=”1″]

Martin Conway has over 40 years’ experience in the contact lens field as a qualified Contact Lens Optician. He is registered with the UK General Optical Council on the Speciality Contact Lens Register. Martin is a fellow of the British Contact Lens Association (FBCLA), and The International Association of Contact Lens Educators (FIACLE). He has served in the Professional Services role as an educator and clinical adviser on behalf of both Sauflon and CIBA, and now acts as Professional Services Consultant for Contamac. Martin has lectured extensively in Europe, Asia, Russia, North and South America and the Middle East.

[us_separator size=”small” show_line=”1″]
[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

Pinguecula and Scleral Lenses

[us_post_title][us_post_date]

By Martin Conway

There are occasions when an elevation on the surface of the conjunctiva such as a pinguecula may be compromised by the edge of a scleral lens. This can cause irritation and injection, but most labs can offer a solution to this problem, and it should not deter the practitioner from proceeding with what would otherwise be a successful fit.

Fluorescein shows how the pinguecula has lifted the lens causing the Optic Zone junction into the epithelium.

Same eye fitted with a toric periphery showing flat axis markings along 10 degrees.

In order to ensure that the notch or elevation locates in the correct position upon insertion, it is advisable to stabilise the lens using prism ballast, or more preferably by refitting with a toric periphery.

Remember you can consult your lab and each lab has their own fitting philosophy. The suggested process to describe what lens you require for this issue is:

  1. Locate the position of the pinguecula in relation to the location markings on the fitting lens, i.e. “ along 190 degrees”.
  2. Describe the width of the notch as an angular measurement using the narrow beam and the axis guide on the slit lamp. i.e. 20 or 30 degrees.
  3. Describe how far into the matrix of the lens you wish to ingress i.e. 1.5 or 2.0 mm.

Some labs may offer an elevated section rather than a notch. The same process applies, however:

  1. Stabilise the lens, locate the direction of the elevation in relation to the lens markings.
  2. Use an angular measurement to describe the width of the elevation, but in the case of an elevation, you will need to specify the height required (up to 600 micron).

The final instruction to the lab, for a notch, will therefore be: “Notch along 190 degrees. 30 degrees width, 1.5 mm deep.” The lab will cut into the lens using a standard tool (normally around 8.00 mm radius) to give a smooth rounded curve and avoid contact with the pinguecula.

Refitted with toric periphery and notch. No injection, good alignment around remainder of the landing zone.

The graphic below shows how Valley Contax illustrates edge vaults with their Custom Stable Lens.

Thank you to Falco Kontaktlinsen (lens on eye) and Valley Contax (edge vault graphic) for contributing imagery to this article. 

[us_separator size=”small” show_line=”1″]
[us_image image=”10392″ has_ratio=”1″]

Martin Conway has over 40 years’ experience in the contact lens field as a qualified Contact Lens Optician. He is registered with the UK General Optical Council on the Speciality Contact Lens Register. Martin is a fellow of the British Contact Lens Association (FBCLA), and The International Association of Contact Lens Educators (FIACLE). He has served in the Professional Services role as an educator and clinical adviser on behalf of both Sauflon and CIBA, and now acts as Professional Services Consultant for Contamac. Martin has lectured extensively in Europe, Asia, Russia, North and South America and the Middle East.

 
[us_separator show_line=”1″ size=”small”]
[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

Making a Difference with Sclerals

[us_post_title][us_post_date]

By Martin Conway & Mark Darling

The rapid growth in the use of scleral lenses over the past few years, has meant that many practitioners have now added the option of a scleral lens design to their armoury of lenses to offer prospective wearers.

At Mark Darling’s clinic in Northampton, we have been fortunate in having a close working relationship with a local ophthalmology department and have been receiving regular referrals for scleral lens fitting. This has ensured a continuing and varied supply of patients, which started as a trickle some three years ago and has increased to a steady flow over the intervening period.

This arrangement has helped improve our skill base considerably. Prior to this, opportunities to fit scleral lenses were few and far between, and without this continuity of supply, it was difficult to assimilate the knowledge base that each successive fit contributes towards.

Originally we were using a design that we were both familiar with. The advantage of this is that you become familiar with the parameters of the lens, and the fluorescein patterns and edge clearances to be expected, but with the variety of cases coming through, it soon became clear that limiting ourselves to a single design was limiting our effectivity in achieving satisfactory outcomes for all patients. In my role as Professional Services Consultant for Contamac, I am fortunate in having access to a multitude of designs from our partner labs around the globe and was able to introduce a variety of different designs into the practice.

Whilst most sclerals are a three zone format, consisting of Central, Limbal and Landing zones, there are a multitude of combinations of curves, tangents and peripheral designs that provide for genuine differences between brands.

This was highlighted recently when a Mr SL, a 52 year old was referred to us from the local hospital. He had had a trauma to his left eye some time ago and noticed his vision deteriorating in the right eye. His best corrected VA’s were R 6/12, L 6/24. The full thickness graft in the left eye was off-centre and much larger than normal at approximately 10mm. The original treatment was conducted in the Caribbean after the patient was hit in the face with a soccer ball. Whilst this would not normally result in a rupture of the cornea, during his investigation Mark discovered that the cause of the deterioration in vision in the right eye was probably due to the advancement of undiagnosed keratoconus. Mark presumed therefore, that an existing pronounced cone in the left with associated corneal thinning, was responsible for the ease of rupture and the need for the larger than normal graft.

Our first choice lens was a design with a gently sloping limbal zone. This worked well on the right eye, providing good comfort and improved VA to 6/6. It was clear however, that the limbal profile of this design would not accommodate the irregular contours of the peripheral cornea in the left eye. The raised edge of the graft needed to be cleared and its proximity to the limbus called for a much steeper profile than our first choice could offer, even with adjustment. Another design was selected which avoids all limbal touch with higher degrees of clearance. This results in a much steeper limbal profile that our first choice lens.

RE showing clearance and landing with first choice design

LE showing graft and reduced clearance, even with steeper limbal design.

Second Trial lens with increased sag

The first lens barely cleared the graft, the next steeper from the trial set cleared by 367 microns initially and it was decided to allow the patient to wear this, rather than risk any contact with the graft interface.

Mark saw the patient and at one week acuities were R 6/7.5, L 6/12. Wearing time was all day in comfort.  Once settled we intend to reduce central clearance by either reducing the base curve or more likely, using a reverse curve. The excessive clearance at this stage was not causing any issues or fogging, but we feel that some additional improvement in acuity should be possible by reducing central clearance.

The incidence of fogging has become a cause for concern and it has clearly been demonstrated that the problem can be controlled with a more closely aligned fit, but for the novice fitter it is probably better to be on the side of caution as we did with Mr SL above. We are fortunate in having the OCT available in the practice and this gives us a much clearer idea of clearances rather than just relying upon fluorescein. Indeed we are now seeing some of our earlier fits come back through for ongoing aftercare and with the benefit of experience (and the OCT!), we are now aiming to reduce clearances on some of our earlier fits.

Scleral lenses are the hot topic at all conferences around the globe and with the complex array of different conditions and topographies that they can be used with, it is unreasonable for any one design to be suitable for all and it is essential that the practitioner provide themselves with as much choice as possible.

For most of us, scleral fitting did not feature in our college courses, so we are all starting with little experience and have to be guided by lens designers and whatever information we can gain through manufacturer’s workshops and fitting courses. They are a very forgiving mode of wear, no matter how daunting a prospect it might seem initially, the difference you can make to someone like Mr SL returns a level of professional satisfaction unmatched with almost any other type of lens.

Thank you to Mark Darling, B.Sc. (hons), MBCO Mark Darling Eyecare & Opticians Northampton, U.K. for contributing to this article.

[us_separator size=”small” show_line=”1″]
[us_image image=”10392″ has_ratio=”1″]

Martin Conway has over 40 years’ experience in the contact lens field as a qualified Contact Lens Optician. He is registered with the UK General Optical Council on the Speciality Contact Lens Register. Martin is a fellow of the British Contact Lens Association (FBCLA), and The International Association of Contact Lens Educators (FIACLE). He has served in the Professional Services role as an educator and clinical adviser on behalf of both Sauflon and CIBA, and now acts as Professional Services Consultant for Contamac. Martin has lectured extensively in Europe, Asia, Russia, North and South America and the Middle East.

[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

Conjunctival Scarring Case Report

[us_post_title][us_post_date]

By Martin Conway

Conjunctival Scarring 

conjunctival-scarring-case-report-x

Many conditions can cause the conjunctiva, the thin transparent membrane that covers the white of the eye and the underside of the eyelids, to become scarred. Scarring damages the conjunctiva and prevents it retaining the protective mucous layer, which helps tears adhere to the surface. Patients may have symptoms of dry eye, with grittiness, burning and in severe cases, loss of vision due corneal tissue loss.

On a global scale, a major cause of conjunctival scarring and blindness an infectious disease called trachoma, which is not common in temperate climates but affects millions of people in North Africa and South Asia.

Cicatrising Conjunctivitis

The term “ cicatrising” means scarring, but is generally reserved for scarring where there is significant tissue shrinkage, usually with distortion of the fornices and/or lids.
There are many causes of scarring: Trauma, Surgery, Infectious Conjunctivitis (Rare), Allergy (Vernal or Atopic Keratoconjunctivitis), can all induce scarring.
Severity can vary from trivial to sight threatening.

Pharmacological Treatments

A variety of pharmacological treatment may be used; artificial tears and ointments to aid lubrication, as well as topical or systemic immunosuppression if of autoimmune aetiology. Conjunctival or buccal mucous membrane grafts, stem cell transplantation, amniotic membrane transplantation and lid surgery are possible ophthalmological interventions.

Therapeutic Contact Lenses

All types of lenses have been used, but the lens of choice for a particularly dry eye is a scleral lens.

Case Study: Atopic keratoconjunctivitis with conjunctival cicatrisation

Practitioner: Mark Darling UK.

Patient: Ms S Female Age: 38

dry-eye-under-scleral
Ms S. original scleral showing lose debris under lens

History: Ms S had vernal keratoconjunctivitis as a child and now has atopic keratoconjunctivitis with secondary ocular surface failure, due to chronic inflammation. She is dependent on topical steroids to control ocular inflammation and discomfort, together with a range of lubricants, vitamin A ointment and other medication as necessary, when her eyes are severely inflamed.

Unaided acuity was 6/60 improving to 6/24 with pinhole in the right eye, and 6/24 improving to 6/18 with pinhole in the left.

Tear production is healthy, although the right upper tarsal plate showed severe cobblestone papillae. The left upper tarsus is less affected. Cicatrisation (scarring) is present in both eyes and the fornix depths are reduced in all four eyelids. She has ocular surface failure in both eyes (R>L), with diffuse punctate epitheliopathy and corneal vascularisation.

conjunctival-scarring-case-report-2
RE Ms S. Slit Lamp image showing scarring, neovascularisation and diffuse epitheliopathy

conjunctival-scarring-case-report-3
The degree of corneal tissue loss and irregularity is seen more clearly in the OCT image above.

Scleral Lens Fitting: Ms S was originally fitted with SoClear lenses some 5 years ago. These improved vision and comfort, but tended to move excessively. She was then, refitted with a larger design (17mm) by another practitioner about one year before her visit to Mark Darling’s practice. The larger diameter had not solved the problem. Ms S said that the lens “clicked” as she blinked. Slit lamp examination showed significant debris collecting under the lens as it moved under the action of the blink, causing discomfort and inflammation.

Initially a conventional 16mm design was tried, but again it tended to move excessively. Mark concluded that the excessive movement was probably caused by the increased traction between the scarring on the upper tarsal plate and the front surface of the lens.

Mark had recently taken delivery of a new lens design , Comfort 15 from No 7 Contact Lenses, in Optimum Extra. This is a 15mm lens with a design offering limbal clearance and a relatively small scleral footprint.

A stable and comfortable fit was eventually obtained by using a steeper central clearance than is normally advised and acuities of R 6/12 L 6/9.5 were obtained. No blanching of vessels occurred, despite the apparent compression of the landing zone. A sealed and stable fit was obtained and the higher clearance did not affect the acuities.

Lenses Dispensed:

R 7.80/15.0 +1.75 L 7.70/15.0 +0.75/-1.50 x 155

(LE front surface toric with prism stabilisation.)

Comfort 15 lenses, No7 Contact Lenses in Optimum Extra

conjunctival-scarring-case-report-4
OCT image of LE showing limbal clearance and narrow landing zone of Comfort 15

The increasing availability of designs using a variety of fitting philosophies, enable practitioners to now have a number of options available to them when confronted by patients with more challenging conditions.

[us_separator size=”small” show_line=”1″]
[us_image image=”10392″ align=”center” has_ratio=”1″]

Martin Conway has over 40 years’ experience in the contact lens field as a qualified Contact Lens Optician. He is registered with the UK General Optical Council on the Speciality Contact Lens Register. Martin is a fellow of the British Contact Lens Association (FBCLA), and The International Association of Contact Lens Educators (FIACLE). He has served in the Professional Services role as an educator and clinical adviser on behalf of both Sauflon and CIBA, and now acts as Professional Services Consultant for Contamac. Martin has lectured extensively in Europe, Asia, Russia, North and South America and the Middle East.

More articles by Martin Conway:

Wettability of GP Materials

[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

Use of Increased Centre Thickness SiHy Lens Design in Keratoconus

[us_post_title][us_post_date]

Patient: CF Male Age: 30

History: OD Keratoconus, Stromal Rings and Cross–Linking, Punctum Plug
OS Keratoconus, Stromal Rings.

The patient had been previously been fitted with RGP lenses but never achieved more than 3 hours wearing time. He is a physiotherapist and plays football semi-professionally several times a week. He could not use RGP’s for his sport.

Uncorrected Vision: OD CF | OS 20/30

Spectacle Rx: R -11.25-7.25×65° | OS 0.00

orbscan
Summary: The patient presented with poor tolerance to RGPs. He was initially evaluated with a soft toric which, although comfortable, gave unsatisfactory vision of just 20/100. A specialist keratoconic soft lens design with increased centre thickness improved vision to 20/80. Finally, a design from Lab Keratos which incorporates a much thicker central zone gave improved comfort along with a much-improved visual acuity of 20/25. Currently he uses the lenses for all working hours, and also for football. Despite the much increased centre thickness, after 3 years of wear no signs of injection or neovascularisation have been observed.

black

Lens Type Fitted:
OD Soft Lens for keratoconus of Lab Keratos
Material: CONTAMAC DEFINITIVE Silicone Hidrogel 74% water DK 60

[us_separator size=”small” show_line=”1″]
[us_image image=”7200″ has_ratio=”1″ ratio=”3×4″]

This edition’s case report was submitted by Isabel MacDonald, a Contact Lens Specialist from Argentina. The case describes the success of a silicone hydrogel lens with increased centre thickness made from Definitive 74 by Lab Keratos.
Isabel MacDonald.

[us_separator size=”small” show_line=”1″]
[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]

Partial Aniridia and Aphakia, following full-thickness penetrating corneal laceration

[us_post_title][us_post_date]

LC Female 63

History

Following a full-thickness corneal laceration sustained in a car accident in 1974, LC was left with a partial aniridia, aphakia and corneal scarring. Visual acuity was Hand Movements Only. PMMA lens fitting was attempted, but poor va, extreme photophobia and discomfort meant that spectacles have been worn for the past 30 years. Sunglasses need to be worn on even overcast days because of extreme light-sensitivity. The patient was also very conscious of the tendency of the right eye to “wander”, which she felt drew attention to the injury.

case_studies_linda01

Spectacle Rx

R -6.00 (balance) HMO; L -5.25/-1.25×30 (+2.25 add) 6/6 n5

Medications

Xalatan drops are used to control the IOP in the right eye mainly, but occasional use in the left has been advised due the side effect of the drops which have a tendency to darken the iris and eyelashes, and may account for the dark brown eye colour!

case_studies_linda02

Topography

case_studies_linda03
(left) Right eye with 10% tint; (right) Right eye with opaque 10%

Lenses Used

Initially a 10% brown tinted lens with clear pupil by Ultravision in Contamac IG 67 was used in the RE. Cosmetically it was acceptable, but vision was not improved and light sensitivity, whilst reduced, was still a problem.

A single-vision lens in Contamac Definitive V3 material was used in the left eye with surprising results. Comfort was good but the patient achieved 6/5 and n6 with the -5.25 single-vision lens!

I can only presume that the reduced pupil aperture (2.0mm), caused by the medication is contributing to the patient’s ability to work in accounts all day without difficulty!

The right lens was the altered to an opaque iris in 10% brown, again in IG67 material from Ultravision, and this eliminated the light sensitivity problem and the 3mm pupil permitted a va of 6/18+ to be achieved.

The patient remains wearing the lenses all day in comfort. She is pleased with the cosmetic result, the eyes are straight and the light sensitivity is eliminated.

[us_post_navigation]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]