Tag: Soft Specialty Lenses

The Changing Landscape of Keratoconus, the Irregular Cornea & Contact Lens Correction

[us_post_title][us_image align=”center” size=”us_600_0″ image=”10509″][us_post_date]

By Eef van der Worp

Keratoconus, without exception, has always been our number one indication for specialty lenses, particularly scleral lenses, for both pre and post-surgical intervention. Studies from the University of Utrecht, Netherlands, by Godefrooij et al.¹ show that the incidence of keratoconus may be much more common than originally thought. The annual incidence of keratoconus is reported to be 1 in 7,500 for the relevant age category or 13.3 cases per 100,000. The prevalence of keratoconus in the general population was estimated to be 1:375. These values appear to be 5-fold to 10-fold higher than previously reported. Two reasons for this may be the ever-increasing use of corneal topographers in practices globally and increased awareness of the condition. 

So, because keratoconus is here to stay – as is secondary ectasia (often resulting from refractive surgery) – this will remain a key consideration in every specialty lens practice. For severe irregularities in stage 3 and stage 4 keratoconus, scleral lenses come to the rescue – as they bridge over the entire cornea, resting on the scleral portion (the conjunctiva, really) on the ocular surface. This explains, at least in part, the vast success of scleral lenses over the last decade.

Cross-Linking

However, the landscape of the irregular cornea in keratoconus seems to be changing. First came the development of corneal cross-linking (CXL), which has now been around in Europe for 20 years (human studies of UV-induced CXL began in 2003 in Dresden, Germany). CXL does not cure or diminish keratoconus but can help stop further progression at a given stage. The primary purpose and literal definition of CXL is to halt the progression of ectasia, although this is not always entirely feasible. Typically, the earlier in life that the procedure is performed, the better the result. That said, the best candidates for CXL are individuals with a progressive ectatic disease of the cornea, so ECPs must monitor that first before the procedure is considered. In other words, the cornea is already irregular to at least some degree by then, and preventative CXL is not feasible.

So, while across Europe, and increasingly in other parts of the world, CXL is becoming the standard of care for young patients with progressive ectatic disease, it is most likely we will see more keratoconic patients. However, it is to be expected that we will see corneal changes in the earlier stages of the condition. This may impact what correction methods we apply: glasses and soft (specialty) lenses may become more common as the first-line method of vision correction.

Lamellar Corneal Transplants

There have been major developments in corneal transplants for keratoconus and other diseases. Not too long ago, a penetrating keratoplasty – replacing the entire cornea in its full thickness with donor tissue – was the standard procedure. Now, an array of lamellar techniques in which only a portion of the cornea is replaced by donor tissue is increasingly used. This can provide many advantages, one being that the corneal irregularities are far less prominent, as a part of the patients’ original cornea remains intact. 

In the late nineties, a technique of deep anterior lamellar keratoplasty (DALK) was developed by the Netherlands Institute for Innovative Ocular Surgery (NIIOS)². The thought behind this technique is to replace only the diseased part – that is, the connective tissue layer of the cornea – and to fasten it with sutures. The healthy part of the cornea is ‘left in place,’ avoiding many of the disadvantages of a full-thickness corneal transplantation. 

Bowman Layer Transplant 

Recently the NIIOS developed another new surgical technique: Bowman layer transplantation. Just as with CXL, Bowman layer transplantation intends to prevent further deformation of the cornea and delay the need for a corneal transplant. This technique is indicated when the cornea is too thin for CXL. With a Bowman layer transplantation, a thin layer of donor cornea (limited to just a donor Bowman layer) is implanted between the connective tissue layers of the cornea, making the original cornea become firmer. Sometimes even two donor Bowman layers are placed on top of each other on the receiving eye for that purpose. 

Soft Lenses to the Rescue

All these techniques may lead to a significant reduction of severe irregular corneas. This may also mean that scleral lenses will not always be necessary. Eye care practitioners around the globe increasingly consider a soft lens as an excellent first option after glasses fail to provide adequate visual acuity. The advantages of this are obvious: scleral lenses are large and handling is a known issue, wearing time is not always optimal, and limitations such as mid-day fogging, redness and potential intraocular pressure increase are eliminated. Especially the ease of use, comfort and cost are regularly mentioned as a plus for soft lenses. 

This doesn’t always work with standard (off-the-shelf) soft lenses. First, the overall sagittal height of the ocular surface regularly goes beyond 4,000 microns over a 15mm chord in these corneas. Because of this, standard commercially available lenses on the extreme right-hand side of the Pacific SAG charts are recommended³. If this is not feasible, ‘out-of-standard’ soft lenses with higher SAG values can be considered. These have virtually no limit in SAG value height. Customized soft lenses based on corneal topography – with tangential peripheral shapes, almost like a scleral soft lens – are on the market as well (also with monthly replacement in silicone hydrogel materials). The question is: Does it still correct or at least mask the corneal irregularities enough for acceptable vision?

Masking

If the answer to the latter question is negative, there is a newer category of soft specialty lenses specifically for keratoconus. These lenses generally have increased central thicknesses, typically in the 300-450 micron range (a standard soft disposable lens may be 80 microns thick) to (partially) mask the irregularity of the cornea to achieve acceptable vision. Although these lenses can be made in silicone hydrogel materials, the Dk/t is lower because of the ‘t’ (thickness) of the lens, and patients wearing these lenses should be monitored for hypoxia. Some lenses can be ordered in 100-micron steps to increase or decrease thickness. Some lenses also have the option for ‘sector management,’ in which one quadrant can be ordered flatter or steeper (like quadrant-specific corneal or scleral lenses) to align the lens better with the keratoconic eye. 

Illustrative of the latest surge in interest in soft specialty lenses for the irregular cornea is that recently some new soft keratoconus lens designs have entered the market. Some of these also try to improve vision further by using aspheric front optics. Trial sets in some of these lenses are also marked in sagittal height increments. 

In Summary 

So, while on the one hand, corneas don’t get nearly as irregular as they used to for a variety of reasons, on the other hand, the lens material, design and optics of soft specialty lenses are improving. The landscape of the keratoconic/irregular cornea, therefore, seems to be changing. And with that, the landscape for specialty lenses in that indication is also transforming, with a potentially more prominent place for soft lenses in that arena. It may be time to adhere to that – in clinical practice and from an industry perspective. 

Educational Series & the Future

The educational grant over 2022, kindly supported by Contamac, has allowed the author of this article to provide generic specialty lens education around the globe for a better understanding of what we are doing with different specialty lens modalities and to potentially take advantage of all of the possibilities available to us. Topics over the past year included mostly scleral lenses, the use of corneal topography, scleral topography, and myopia management with specialty lenses. But increasingly, soft lens fitting in all its aspects (how to better fit standard lenses, when to go to out-of-standard lenses and soft lenses for the irregular cornea) is gaining more and more attention. According to the annual Eurolens survey published in Contact Lens Spectrum (Jan 2023), at least 86% of all lenses fitted today are soft. But we can’t fit all these patients with standard lenses. The future looks bright for specialty lenses, especially when it comes to soft specialty lenses. We are just beginning to scratch the (ocular) surface. Stay tuned. 

[us_separator show_line=”1″ size=”small”]
Godefrooij DA, de Wit GA, Uiterwaal CS, Imhof SM, Wisse RP. Age-specific Incidence and Prevalence of Keratoconus: A Nationwide Registration Study. Am J Ophthalmol. 2017 Mar;175:169-172
Netherlands Institute for Innovative Ocular Surgery: https://www.niios.com/melles-cornea-clinic/treatments/
van der Worp E, Lampa M, Kinoshita B, Fujimoto MJ, Coldrick BJ, Caroline P. Variation in sag values in daily disposable, reusable and toric soft contact lenses. Cont Lens Anterior Eye. 2021 Dec;44(6):101386. doi: 10.1016/j.clae.2020.11.006. Epub 2021 Jan 8. PMID: 33423977.
[us_separator show_line=”1″ size=”small”]
[us_image image=”9904″ size=”us_600_600_crop” has_ratio=”1″ ratio=”3×4″]

Eef van der Worp is an educator and researcher. He received his optometry degree from the Hogeschool van Utrecht in the Netherlands (NL) and has served as a head of the contact lens department at the school for over eight years. Eef received his PhD from the University of Maastricht (NL) in 2008. He now runs his own research & education consultancy ‘Eye-Contact-Lens’ which is based in Amsterdam (NL). He is a fellow of the AAO, BCLA and the SLS, a lifetime fellow of IACLE and an honorary life member of ANVC. He is on the education committee for the GSLS and the OVN.  Eef is adjunct assistant Professor at Pacific University College of Optometry (Oregon, USA), and adjunct Professor at the University of Montreal University College of Optometry (CA) and he is lecturing extensively worldwide and is a guest lecturer at a number of Universities in the US and Europe.

[us_separator size=”large”]
[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , ,

Using a Customized Soft Lens

[us_post_title]

Sometimes ‘flat out’ the best option for a flat eye

[us_post_date]

By Gerard Smits

Introduction

The vast majority of the lenses we fit in contact lens practice are soft lenses. The amount of attention that goes into ‘fitting’ soft lenses is limited in contrast to the focus on scleral lens fitting, corneal lens fitting, and orthokeratology, for instance. This case shows how taking control of the fitting process can sometimes enhance someone’s life and upgrade one’s vision in relation to quality of life. 

Subjective

Mary came to our practice right in the heart of Amsterdam in the Netherlands. Her wish was to wear lenses in addition to the glasses that she used, with a preference for daily disposables if possible. The anamneses did not reveal any specific considerations or limitations for fitting with a soft lens. Patient complains of moderate dry eye symptoms.

Objective

General slit lamp examination revealed no abnormalities. We focus on the right eye of the patient for this case report. Refraction of the right eye came down to S+2.75, with a corneal diameter (white-to-white with the Medmont topographer) of 12.0mm with an overall average eccentricity of over four quadrants of 0.43.

In our contact lens practice, emphasis is on the shape of the entire anterior ocular surface, not just the central cornea. We use a Medmont corneal topographer for this reason, but with a special tool: the E-H software¹. 

Based on the overall corneal topography using that instrument, combined with the peripheral corneal angle measured with the topographer and using the sagittal height calculator – the overall sagittal height of the ocular surface (OC-SAG) over 15mm can be estimated, typically the horizontal meridian values are used.

In this case, the E-H 0-180° value 3524 microns. This figure is well below the OC-SAG of the average eye, which is estimated to be in the 3750 micron range. This eye also falls outside the one-standard deviation range (1-SD), which is between 3550-3950 microns.  

[us_separator][us_image image=”10467″ size=”us_768_0″ align=”center”][us_separator]

Assessment

The fact that this eye falls outside (on the left side) of the normal distribution bell-curve and even outside the 1-SD range – indicates that this is an exceptionally flat eye. Based on keratometry values alone (8.09/7.88) it is not easy to make the same judgement, especially as the eye has an average e-value and standard corneal diameter. In cases like this, measuring the full ocular surface over at least the diameter of the soft lens (or the benchmark 15mm is used as a standard often) can be very insightful. 

For this patient, several standard soft lenses were tried, including Dailies Aqua Comfort Plus (Alcon) BC 8.70 Ø 14.0, Clariti 1 Day (CooperVision) BC 8.60 Ø 14.1, Dailies All Day Comfort BC 8.60 Ø 13.80 and monthly disposable Biofinity (Alcon) BC8.60 Ø 14.0 and Fresh Excellent (Microlens/Wölk) BC 8.3 Ø 13.6. All lenses failed because of lack of movement and mobility, in addition to poor comfort.

Plan

Patient ultimately was refitted with a custom soft lens based on the patient’s corneal topography. The Medmont file was­­­ uploaded to the manufacturer and an individual monthly disposable silicone hydrogel lens was created for this patient. The Indivisual (Menicon, Emmen NL) was manufactured in the Definitive 74 material (Efrofilcon A V3) with a sagittal height of the lens (CL-SAG) of 2900 micron and a tangential peripheral shape (tangent angle 54°) S+2.50 in a Ø 14.1. 

The lens design is similar to how many scleral lens designs are configured these days. The lens fit procedure would also be close to fitting a scleral lens: changing the tangent angle would ‘lift’ the lens, decreasing the lens to a lower sagittal height. For this patient, this lens design resulted in an optimal lens fit with excellent movement – which is believed to be the result of the tangential peripheral shape of the lens in conjunction with the customized CL-SAG height. 

In Summary

Using the overall sagittal height of the ocular surface over a 15mm chord can give the eye care practitioner (ECP) valuable information about when to start with a flat or steep lens (a low or high CL-SAG) using the Pacific University SAG-charts, or when to divert to an out-of standard or a customized lens – like in this case. This will save time, on behalf of the patient and the ECP, from fewer trial lenses used and increased overall satisfaction. Consequently, this can potentially prevent drop-out of soft lens wear. 

The initial lens type requested by the patient, daily disposables, come in a variety of brands but are limited in size and parameters. It is the task of the ECP to assess and decide which lens is suitable for a given eye and which is not. This case perfectly illustrates the decision-making process, and a custom-made lens in a silicone hydrogel material with a monthly replacement schedule is the ideal solution for the patient. The patient still desires a daily disposable lens, if possible, but that is not feasible in this case. As ECPs we must be clear about this. In regard to the patient’s complaint of moderate dry eye symptoms – as ECPs we must be careful with that. Any form and type of eye discomfort can be easily mistaken for dry eye. But often, lens fit pro­­blems are partially or fully the root cause of discomfort issues, and lens fit issues need to be addressed first. The ‘take-home message’ in this case was pretty obvious: a flat lens for this flat eye was the best technical option for this patient.  

¹the E-H tool in the Medmont topographer can be added simply, using the manufacturer’s guidelines. 

This case study is part of a series focusing on speciality soft lens fitting. Stay tuned for the next installment coming soon. Special thanks to Eef van der Worp for bringing this series together.

[us_separator show_line=”1″ size=”small”]
[us_image image=”10495″ size=”us_600_0″ has_ratio=”1″ ratio=”3×4″]
[us_separator size=”small”]

Gerard comes from a long line of opticians (grandparents, father and brother are all opticians). He graduated from the Christiaan Huygenschool (optics) in Rotterdam, and started working as a contact lens specialist in 1985. Since then he has been a member of the ANVC (Dutch Contact Lens Association). He has specialized in both rigid and soft lens fitting and has worked as a consultant for many industry partners, and tested different (specialty) lenses in his practice for the industry. He works as Ralph Optiek in the center of Amsterdam. His experience includes specialty lenses, such as orthokeratology, rigid corneal lenses after refractive surgery and fitting of custom soft lenses. Customization of lens fiting using corneal topography data and multifocal (rigid corneal and soft) lens fitting are two of the main challenges, but also opportunities he sees for your profession.

[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , , , ,