Tag: GP lenses

Avoiding a Corneal Transplant in a Young Patient

[us_post_title][us_post_date]

By William Skoog OD, FAAO

Affiliations: Illinois College of Optometry

Background

Corneal opacity is the fifth leading cause of blindness worldwide¹. A common cause of corneal opacity is infectious keratitis. In developed countries, contact lenses are the leading cause of infectious keratitis while in developing countries it is from corneal trauma during agriculture work¹. The most common organism responsible for microbial keratitis in contact lens wear is Pseudomonas aeruginosa². When the visual axis is involved, a cornea transplant may be required to improve vision. Corneal transplants have a higher rate of rejection in younger patients³. 

Case Description

A 19-year-old Hispanic female presented for a gas permeable contact lens fitting. Her ocular history was remarkable for microbial keratitis OS caused by Pseudomonas following extended wear of an unknown monthly soft contact lens. 

Entering visual acuities were 20/20 OD with correction and 20/200 OS without correction which improved to 20/40 with pinhole. All other entrance testing was unremarkable.

Slit lamp examination revealed a 6 mm round, central stromal scar with significant stromal thinning OS (Figure 1). 

Simulated keratometry measurements were taken from tomography and were 40.75/43.0 @ 89 OD (Figure 2), 33.75/35.50 @ 99 OS (Figure 3). 

Manifest Refraction was -7.00-1.50×170 OD with a distance acuity of 20/20 and +2.00 sphere OS with a distance acuity of 20/80. 

Due to the decrease in VA secondary to a central corneal opacity a diagnostic scleral lens was applied to the left eye to determine visual potential. The initial diagnostic lens that was applied to OS was a prolate lens (Table 1A) that showed excessive central fluid reservoir clearance (Figure 4A). Her VA improved to 20/30 with an over-refraction. Since there was a vast improvement in VA with a scleral lens, the decision was made to peruse wearing a scleral lens OS. The final lens order was changed to an oblate design (Table 1B) which improved the central fluid reservoir clearance (Figure 4B). 

Optimum Extreme, a high-DK material was selected to allow the compromised cornea to receive as much oxygen as possible while she was wearing the lens. Since the initial corneal insult happened because of non-compliance, the importance of contact lens hygiene, wearing schedule, cleaning regimen and proper filling solution was discussed at length with her and her parents. 

She was closely followed over the first three months of scleral lens wear to ensure appropriate wear.

[us_separator size=”small”][us_image image=”10663″ size=”us_600_0″ align=”center”]

Figure 1: Slit lamp photo showing a 6mm round central stromal scar OS secondary to microbial keratitis.

[us_separator]
[us_image image=”10665″ size=”us_600_0″ align=”center”]

Figure 2: Axial map showing with-the-rule astigmatism in the right eye.

[us_image image=”10664″ size=”us_600_0″ align=”center”]

Figure 3: Axial map showing central corneal flattening secondary to microbial keratitis in the left eye.

[us_separator]
[us_image image=”10666″ size=”us_600_0″ align=”center”]

Figure 4A: An AS-OCT of a prolate diagnostic scleral lens OS showing excessive central vault with adequate mid-peripheral vault.

[us_image image=”10667″ align=”center” size=”us_600_0″]

Figure 4B: An AS-OCT of an oblate scleral lens design OS showing adequate central clearance after ~6 hours of wear.

[us_separator]
Type Power BC Diameter Edge Design
Onefit 2.0 Plano 8.4 14.9 std Prolate

Table 1A. Initial diagnostic scleral lens OS that showed excessive central clearance

[us_separator]
Type Power BC Diameter Edge Design Material
Onefit 2.0 +6.50 8.4 14.9 std Oblate – CCR 230 Optimum Extreme

Table 1B. Final scleral lens design OS 

[us_separator size=”small”]

Conclusions

Corneal scarring after microbial keratitis leads to vision loss secondary to corneal opacity and irregular astigmatism⁴. The two most common options to improve vision in these cases are corneal transplantation or a specialty contact lens. Corneal gas permeable or scleral contact lenses should be considered if they are able to provide the patient with functional vision as was demonstrated in this case.

[us_separator show_line=”1″ size=”small”]
1. Ting, D.S.J., Ho, C.S., Deshmukh, R. et al. Infectious keratitis: an update on epidemiology, causative microorganisms, risk factors, and antimicrobial resistance. Eye 35, 1084–1101 (2021). https://doi.org/10.1038/s41433-020-01339-3
2. Tan, S., Walkden, A., Au, L. et al. Twelve-year analysis of microbial keratitis trends at a UK tertiary hospital. Eye 31, 1229–1236 (2017). https://doi.org/10.1038/eye.2017.55
3. Gulias-Cañizo R, Gonzalez-Salinas R, Hernandez-Zimbron LF, Hernandez-Quintela E, Sanchez-Huerta V. Indications and outcomes of pediatric keratoplasty in a tertiary eye care center: A retrospective review. Medicine (Baltimore). 2017 Nov;96(45):e8587. doi: 10.1097/MD.0000000000008587. PMID: 29137083; PMCID: PMC5690776.
4. Singh K, Jain D, Teli K. Rehabilitation of vision disabling corneal opacities: is there hope without corneal transplant? Cont Lens Anterior Eye. 2013 Apr;36(2):74-9. doi: 10.1016/j.clae.2012.10.085. Epub 2012 Nov 27. PMID: 23199902.
[us_separator show_line=”1″ size=”small”]
[us_image image=”10662″ size=”us_600_600_crop” has_ratio=”1″]

Dr. Skoog is a clinical instructor at the Illinois College of Optometry in the cornea and contact lens department, where he previously completed a residency. He lectures on anterior segment disease and contact lenses. He has no disclosures.

[us_separator size=”large”]
[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , , , , ,

The Changing Face of Contact Lens Fitting

[us_post_title][us_post_date][us_image image=”10284″ size=”us_600_0″ align=”center”]

By Martin Conway

In the October 2022 edition of Contact Lens Spectrum, Ed Bennett’s report on the GP and Custom Soft Annual Report 2022 provided a comprehensive insight into the prescribing habits of top US practitioners. Scanning the list of subscribers, they are mainly Key Opinion Leaders and researchers, so this may not necessarily be indicative of what is going on in the rest of the US market, much less in diverse markets around the world. It does, however, give a good indication of the direction the contact lens industry will take over the next ten years or so.

We also see the growth of interest in the control of myopia with both soft and GP ortho-k, as well as the continued use of scleral lenses – none of which should surprise us.

Another prominent trend is the increased use of complex optics such as wavefront-guided lens designs and the correction of Higher Order Aberrations, requiring complex calculations to achieve success. All of which need accurate digital data in order to be effective.

Practitioners fitting ortho-k lenses typically do so with the aid of a topographer and not a fitting set. The recent increased use of scleral lenses has been facilitated, in great part, by the routine use of OCT during normal optometric practice. So we see that increased technology use has already occurred over the past decade or two.

Specialist lens practitioners have long since exchanged their keratometers for topographers; the data produced is then converted by laboratories’ algorithms to provide a points file which is fed directly into a lathe. This delivers an almost guaranteed first-time fit and has replaced the need for fitting sets for ortho-k and regular corneal lenses. Laboratories also benefit by not having to provide dozens of fitting sets, many of which are seldom used, and the practitioner benefits from fewer refits and reduced chair time.

The information provided by a Placido Ring-based instrument does not cover the entire cornea, and although a vast improvement on the keratometer, a certain amount of extrapolation is required in order to give information up to and beyond the limbus.

Enter the Corneal Profilometer. For some years, the suppliers of these instruments have been extolling the virtue of their advantages over conventional topography. These have had limited success in Europe, but the US market appears to have accepted the concept more readily than elsewhere. This is perhaps because of the more rapid uptake of scleral lenses in that market, and it would appear from the report that their use is now becoming more mainstream.

The information produced by these new instruments allows for more personalised designs to be created, incorporating edge profiles that exactly match the patient. Again, the information collected by the instrument provides the raw data for an algorithm that ultimately feeds the lathe with data in order to produce the finished lens.

Scheimpflug-based instruments are also available on the market, which will, not only collect data over the entire cornea and provide 360-degree imagery but also download that data to an online lens design module that, in turn, instructs the lathe directly.

There is now a small but growing interest in fitting intra-limbal designs for regular corneae because of the additional comfort they provide for the new wearer. Experience with ortho-k designs, which tend to be slightly larger and more comfortable than normal GP designs, has persuaded practitioners that larger diameter lenses might offer greater comfort than conventional designs for their regular patients.

Although these designs have been suggested for some time, practitioners found the unfamiliar fluorescein pattern produced by these larger lenses confusing, and apart from a few dedicated followers, their use has been limited.

With accurate data from the limbal area and beyond, this modality should develop further as algorithms take over the need to learn new skills. Those practitioners already using this type of lens describe the comfort as similar to soft lenses within two hours of wear, yet with the visual acuity typically associated with GP lenses.

Looking forward, I can see that practices wishing to develop their speciality contact lens business will need to commit to investing in instrumentation within their practice. Either in the new generation of topographers, which can provide a composite picture of the complete cornea and beyond, one of the Corneal Profilers, or Scheimpflug anterior chamber imaging systems.

As lens designs develop and provide increased comfort and vision for myopia management, ectasia, and other ametropias, more opportunities will open up for the profession. These opportunities will require accurate data to be provided to the laboratory, and consequently, laboratories will need to be set up to receive this digital data and apply it to their new and existing designs.

Practices that do decide to invest in their speciality lens business can look forward to reaping the benefits that these instruments permit. They will differentiate themselves as patients appreciate the level of investment and enjoy the increased comfort and visual benefits they provide.

These developments will not come about overnight. Ed Bennett’s report gives a snapshot of what is happening within some very sophisticated and specialised practices, and the US market has a significant influence on how the worldwide market will develop.

We can look forward to exciting developments over the next few years, led by diagnostic technologies that will change the way bespoke contact lenses of all types are supplied.

[us_separator show_line=”1″ size=”small”]
[us_image image=”8848″]
[us_separator size=”small”]

Martin Conway has over 40 years’ experience in the contact lens field as a qualified Contact Lens Optician. He is registered with the UK General Optical Council on the Speciality Contact Lens Register. Martin is a fellow of the British Contact Lens Association (FBCLA), and The International Association of Contact Lens Educators (FIACLE). He has served in the Professional Services role as an educator and clinical adviser on behalf of both Sauflon and CIBA, and now acts as Professional Services Consultant for Contamac. Martin has lectured extensively in Europe, Asia, Russia, North and South America and the Middle East.

[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , , , ,