Introduction

This patient is a 51 YO female who had bilateral Penetrating Keratoplasties around 30 years ago in Rotterdam. Her grafts have become ectatic over the years and now exhibit signs of Rim Ectasia. This presents itself as a thinning of the host cornea leading to a tilting of the graft and a significant increase in irregular astigmatism.

[us_separator]
[us_image image=”10824″]

Right Topography 

[us_image image=”10823″]

Left Topography

[us_separator size=”small”]

Her current spectacle prescription is: 

R -2.50/-6.50×50              6/7.5 

L +1.25/-12.75×125         6/7.5- 

Her visual acuity with the spectacles is good but her occupation as a Paediatric Doctor means her glasses are an inconvenience and after seeing the Corneal Consultant, she was referred to me for a contact lens fitting. The amount of irregular astigmatism and the fact that the grafts are tilted forward superiorly means that even in a post-graft design, corneal GPs would be unsuitable. After a discussion with the patient, we decided to fit some mini-sclerals. The patient had previously worn full 22mm sclerals in the past and was receptive to the idea of mini-sclerals. 

Initial fitting appointment 16/4/21 

Trial with OneFit Med, Blanchard laboratory, Canada 

Several lenses were trialled before a pair of lenses were found which cleared the cornea in both eyes.  

The image below shows one of the lenses trialled with excessive clearance over the whole cornea, which illustrates the extent of the Rim Ectasia in this patient. 

[us_separator][us_image image=”10825″ align=”center”][us_separator size=”small”]

Finally, the 5450μ lens for the RE and the 5750μ for the LE were used.

  Right Eye Left Eye
Lens 5450 μ sag -10.00 toric periphery 150 μ 5750 μ sag -11.00 toric periphery 150 μ
O/R -2.50/-1.50×120 -4.00/-1.50×40
V/A 6/7.6++ 6/6-

The lenses were allowed to settle for 40 minutes before over-refraction and then OCT scanning was conducted using the MS-39 AS-OCT from CSO Italia, which produces a 16mm image size and can image the full diameter of the lens in situ.

The OCT images showed central clearance of R 175 μ and L 200 μ however there was a significant amount of touch in the 12 O’clock position on both eyes L>R.

The flat axes of the toric periphery aligned with the corneal astigmatism at R 120 and L 40 and were tight along these axes.

The lenses required an increased height at the areas of superior touch; with the OneFit Med this is achievable in two zones at 9.5mm and 12.5mm, the clearance at 12.5 was good so the M or mid-peripheral zones height would need to be increased by 100μ in each eye. The toricity would also need increasing, using the online calculator, the new parameters were calculated as follows:

R 5450μ -10.62/-1.50×120 200μ TP M +100μ

L 5750μ -13.12/-2.50×40   200μ TP M + 100μ

It is important to keep the central clearance as low as possible to maximise the oxygen reaching the cornea. For this reason, the lenses were manufactured in the Optimum Infinite material with a 180 Dk to minimise the risk of both Hypoxia and possible corneal decompensation.

Collection appointment 24/5/21

  Right Eye Left Eye
Lens 5450 -10.62/-1.50×120 5750 -13.12/-2.50×40
VA 6/7.6 6/7.6
BEO 6/6 6/6

AS-OCT showed no touch with 200μ of clearance centrally and 80μ of clearance at the M zone.

[us_separator][us_image image=”10826″ align=”center”][us_separator size=”small”]

Px was then instructed on insertion and removal, issued with Hy-Care, Saline, case and instructed to build up wearing time by 1 hour/day to a maximum of 10 hours until the next visit.

Follow-up visit 21/6/21

Wearing time today: 4 hours

  Right Eye Left Eye
Lens 5450 -10.62/-1.50×120 5750 -13.12/-1.50×40
M +100μ + 100μ
TP 200μ 200μ
VA 6/6- 6/7.6
OR -1.00 -1.00
VA -6/6 6/6
BEO 6/6- 6/6-

Scanning the patient with AS-OCT showed that the right lens had settled back and was now touching the superior cornea at approximately 2 o’clock slightly inside the central zone of the lens and caused some edge lift off superiorly.

Some increase in superior clearance was required without increasing the central clearance due to Hypoxia concerns with a thick fluid layer over the graft. The OneFit has a reverse geometry option called Central Clearance Reduction (CCR). This flattens the base curve of the optic zone diameter. In this instance, by using CCR, the flatter base curve lifts the lens away from the protruding graft and has the additional benefit of reducing some of the high minus in the lens power.

The calculator was used to produce the new lens specification taking into account the over-refraction and CCR on the right lens.

  Right Eye Left Eye
Lens 5450 -7.62/-1.50×120 5750 -14.12/-1.50×40
CCR 5450 -7.62/-1.50×120 5750 -14.12/-1.50×40
M +100μ +100μ
TP 200μ 200μ

The existing lenses were retained from the patient as it was too risky for her to keep wearing lenses with corneal touch particularly as it was near the graft/host margin.

Collection appointment 27/7/21

  Right Eye Left Eye
Lens 5450 -7.62/-1.50×120 5750 -14.12/1.50×5
VA 6/6++  6/4.8
Central Clearance 150μ 200μ
M Zone Clearance 85μ 125μ
Edges Aligned well in both eyes; no impingement seen Aligned well in both eyes; no impingement seen

Edges aligned well in both eyes; no impingement seen

The Patient was again instructed to build up the wearing time gradually by 1 hour per day to a maximum of 10 hours and 4-5 days/week.

Follow-up appointment 15/9/21

  Right Eye Left Eye
Lens 5450 -7.62/-1.50×120 5750 -14.12/-1.50×5
VA 6/6  6/6 +++
Clearance 85μ 65μ
TP 200μ 200μ

The patient had built up the wearing time to 5 hours per day 5 days a week which suited her working schedule. The lenses were fitting well with no adverse effects, she was put on a 3/12 recall, sooner if any issues or concerns.

Follow-up appointment 17/1/22

The patient is still happy with her lenses and is able to use them while exercising and scuba diving as well as some time at work. She finds her eyes become slightly red at about 7-8 hours so limits her time to less than that.

  Right Eye Left Eye
Lens -7.62/-1.50×120 5750 -14.12/-1.50×5
VA 6/6 +  6/4.8

The lenses are still clearing the cornea fully, no touch was observed in any meridian.

The corneal consultant has also seen the patient and is happy with her corneal health. She will be seen on a six-monthly review schedule in the contact lens clinic with the option for me to refer her to the corneal clinic if there are any concerns.

[us_separator show_line=”1″ size=”small”]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , ,

Not a Steep Learning Curve

[us_post_title]

Using OC-SAG Data to Assess the Suitability For Soft Lens Wear

[us_post_date]

By Gerard Smits

Introduction

This lens fit appears like a complex case, with at least three different factors playing a role. But by ‘simply’ applying a basic set of rules, this case report shows what a difference an Eye Care Professional (ECP) can make in people’s lives. First, by assessing whether an eye is ‘standard’ or not, the ECP can determine whether one of our standard off-the-shelf lenses would be the best lens option, with many benefits including material choice, pricing and – especially – frequency of replacement. ‘Simply’ because the ocular surface is steep and outside the range of the normal eye, choosing a ‘steep lens’ based on sagittal height can make the difference. In addition, there is the challenge (or not) of the lens prescription and material considerations. Not that complicated at all, and, in fact, without a steep learning curve.

Subjective

Tessa came to our practice right in the heart of Amsterdam in the Netherlands. Her prescription is out-of-standard. The feasibility of a standard monthly lens is explored but was questioned. With her high hyperopic prescription, the cosmetic and visual effects of contact lenses over glasses should not be ignored (large visible eyes, aberrations, magnification and sub-optimal visual acuity with glasses).

In the past, she had tried different lens types, with a long track record including, but not limited to Durasoft 3 (Wesley Jessen), Unilab 42C toric (Taiwan) and StabMax (MicroLens). Reproducibility used to be a major problem in the past with custom-made lenses; a problem that has been mostly relegated with current manufacturing techniques. The patient history did not reveal any special or specific considerations or limitations for fitting with a soft lens, other than that she reported having mild dry eyes.

Objective

General slit lamp examination revealed no abnormalities. Refraction of the patient (in this case report we focus on her right eye) came down to: S+4.75=C -5.00 x 90°. Her sim-K values are 7.36/7.14, with eccentricities reported in four different quadrants as: 0.45 superior, 0.71 nasal, 0.58 inferior and 0.35 temporal.

In our contact lens practice, special emphasis is on the shape of the anterior ocular surface. We use a Medmont corneal topographer with a special tool: the E-H software*. Based on the overall corneal topography using that instrument, the peripheral corneal angle measured with the corneal topographer and using the sagittal height calculator – the overall sagittal height of the ocular surface (OC-SAG) over 15mm can be estimated, typically the horizontal meridian values are used.

Assessment

In this case, the E-H 0-180° value was 4097µm. This is well beyond the OC-SAG of the average eye (which is estimated to be in the 3750µm range). In fact, it falls outside the one-standard deviation range (between 3550-3950µm). The fact that this eye falls on the right side of the normal distribution bell curve and even outside the 1-SD range (accountable for 66.7% of all eyes) – indicates that this is an out-of-standard steep eye. Based on keratometry values alone (7.36/7.14), and even in combination with the eccentricity values this time (0.53, which is standard), it is not easy to judge that in the same way. Her corneal diameter (white-to-white) measured with the Medmont was 11.2mm which is slightly smaller than normal.

In addition, the prescription’s astigmatism does not match the corneal astigmatism data (the difference in central keratometry values is only 0.22mm, which represents roughly an astigmatism of 1 diopter, while the refraction indicates 5 diopters of astigmatism). The refractive (rest) cylinder must therefore come from the crystalline lens or another internal astigmatism in the eye.

[us_separator size=”small”][us_image image=”10692″ align=”center”]

Plan

For this patient, it was decided not to start with standard lenses but go directly to an out-of-standard lens – to satisfy both the refractive and ocular surface shape peculiarities of this patient’s eye.

With any toric lens, but certainly, with an astigmatism of this magnitude, good stabilization of the lens on-eye is crucial. Fitting a toric lens is not a disadvantage, in this case, though – but rather an advantage. Since most soft toric lenses have their toricity based on the inside of the lens – this can help stabilization with higher cylindrical values. In other words: a 5D cylinder stabilizes better most probably than a 0.75D cylinder.

In addition, ECPs can choose to fit a slightly steeper lens, to aid stability of the lens on-eye and/or to choose a larger diameter. But for this, it is important to know how steep the eye is. This cannot be judged by central keratometry values and/or eccentricity alone, as this case shows. The eye is exceptionally steep, and to create stability an even steeper lens would be needed. A 7.70 lens was selected in the end, with a lens diameter that is not larger than normal (because of her corneal diameter). But the result is a lens with an out-of-standard high sagittal height value. Using sagittal height values, in this case, makes more sense than using base curve values. 

A Gentle 80 Toric (Mark’Ennovy, Madrid ES) was used in this case: BC 7.70 S+5.00=C -5.00 x 95° Æ14.0. This is an 80% hydrogel lathe-cut soft lens for monthly replacement. The lens with these parameters is calculated to have a CL-SAG of 4100µm. This material, a non-silicone hydrogel (SH) material was preferred over the silicone hydrogel lathe-cut soft lens variant (Saphir Rx ) for monthly replacement, because of wettability issues with the SH lens material.

In Summary

It can be determined that there are 3 categories of soft lenses:

(1) off-the-rack standard soft lenses; 

(2) out-of-standard lenses with extended parameters;

(3) custom-made individually designed lenses. 

For patients like this, the number 1 category is out of range.

First: the refraction is out of the standard lens’ parameter range. In these cases, category 2 lenses can be a huge asset and can prevent drop-out of lens wear. In this case, it was not just a special optical case, but also an ocular surface shape outlier: an exceptionally ‘steep’ eye that desired a special design with a higher-than-normal CL-SAG. Both optically, and in terms of lens comfort, this lens performs better than previous lenses. As a third variable, the silicone hydrogel lenses originally selected did not provide the desired wettability. Switching to a non-SH solved this problem. Careful checks for hypoxic signs on the eye are monitored. But having the option to switch material, whilst staying in the same lens design – can be a huge plus for ECPs when fitting soft specialty lenses.

This case shows that, albeit ‘complex’ at first, applying simple rules towards (1) eye shape, (2) prescription and (3) material properties can make a big difference in contact lens practice.

*the E-H tool in the Medmont topographer can be added simply, using the manufacturers guidelines.

This case study is part of a series focusing on speciality soft lens fitting. Stay tuned for the next installment coming soon. Special thanks to Eef van der Worp for bringing this series together.

[us_separator show_line=”1″ size=”small”]
[us_image image=”10495″ size=”us_600_600_crop” has_ratio=”1″ ratio=”3×4″]

Gerard comes from a long line of opticians (grandparents, father and brother are all opticians). He graduated from the Christiaan Huygenschool (optics) in Rotterdam, and started working as a contact lens specialist in 1985. Since then he has been a member of the ANVC (Dutch Contact Lens Association). He has specialized in both rigid and soft lens fitting and has worked as a consultant for many industry partners, and tested different (specialty) lenses in his practice for the industry. He works as Ralph Optiek in the center of Amsterdam. His experience includes specialty lenses, such as orthokeratology, rigid corneal lenses after refractive surgery and fitting of custom soft lenses. Customization of lens fiting using corneal topography data and multifocal (rigid corneal and soft) lens fitting are two of the main challenges, but also opportunities he sees for your profession.

[us_separator size=”small” show_line=”1″]
[us_post_navigation in_same_term=”1″]
[us_sharing providers=”facebook,twitter,linkedin” align=”right”]
Tags: , , , , , ,